  general purpose relay ly 1 general purpose relay ly ? arc barrier equipped.  high dielectric strength (2,000 vac).  long dependable service life assured by ag-alloy contacts.  choose models with single or bifurcated contacts, led indicator, diode surge suppression, push-to-test button, or rc circuit.  all models meet ul and csa approvals; vde, lr, and sev approved versions are available. ordering information to order: select the part number and add the desired coil voltage rating (e.g., ly1- dc6 ). note: 1. types with specifications other than those listed are available. contact your omron sales representative. 2. to order connecting sockets and mounting tracks, see ?accessories? section. type terminal contact form model single contact bifurcated contact standard bracket mounting upper mounting bracket lower mounting bracket standard bracket mounting upper mounting bracket lower mounting bracket standard plug-in/solder spdt ly1 ly1f ly1s ? ? ? dpdt ly2 ly2f ly2s ly2z ly2zf ly2zs 3pdt ly3 ly3f ly3s ? ? ? 4pdt ly4 ly4f ly4s ? ? ? pcb spdt ly 1 - 0 ? ? ? ? ? dpdt ly 2 - 0 ? ? ly 2 z - 0 ? ? 3pdt ly 3 - 0 ? ? ? ? ? 4pdt ly 4 - 0 ? ? ? ? ? led indicator plug-in/solder spdt ly1n???? ? dpdt ly 2 n ? ? ly 2 z n ? ? 3pdt ly3n???? ? 4pdt ly4n???? ? diode surge suppression spdt ly 1 - d ? ? ? ? ? dpdt ly 2 - d ? ? ly 2 z - d ? ? 3pdt ly 3 - d ? ? ? ? ? 4pdt ly 4 - d ? ? ? ? ? led indicator and diode surge suppression spdt ly 1 n - d 2 ? ? ? ? ? dpdt ly2n-d2 ? ? ly2zn-d2 ? ? 4pdt ly 4 n - d 2 ? ? ? ? ? rc circuit spdt ly1-cr???? ? dpdt ly 2 - c r ? ? ly 2 z - c r ? ? led indicator and rc circuit spdt ly 1 n - c r ? ? ? ? ? dpdt ly2n-cr ? ? ly2zn-cr ? ?
2 general purpose relay ly note: 1. types with specifications other than those listed are available. contact your omron sales representative. 2. to order connecting sockets and mounting tracks, see ?accessories? section. accessories connecting sockets to order: select the appropriate part numbers for sockets, clips, and mounting tracks (if required) from the following charts. track mounted sockets * track mounted socket can be used as a front connecting socket. back connecting sockets note: types pyp-18, ptp-12 and ptp-10 may be cut to any desired length. type terminal contact form model single contact bifurcated contact standard bracket mounting upper mounting bracket lower mounting bracket standard bracket mounting upper mounting bracket lower mounting bracket push-to-test button plug-in/solder spdt ly 1 l 4 ? ? ? ? ? dpdt ly 2 l 4 ? ? ly 2 z l 2 ? ? 3pdt ly 3 l 4 ? ? ? ? ? 4pdt ly 4 l 4 ? ? ? ? ? led indicator and push-to-test button plug-in/solder dpdt ly 2 l 4 n ? ? ly 2 z l 2 n ? ? 4pdt ly 4 l 4 n ? ? ? ? ? relay socket* relay hold-down clip mounting track standard rc circuit spdt ptf08a-e pyc-a1 y92h-3 pfp-100n/pfp-50n & dpdt pfp-m or pfp-100n2 3pdt ptf11a pfp-s (option spacer) 4pdt ptf14a-e relay solder terminal socket wire wrap terminal socket relay hold-down clip socket mounting plate standard push-to-test rc circuit mtg. plate 1 10 12 18 spdt pt08 pt08qn pyc-p pyc-p2 pyc-1 pyc-s pyp-1 ? ? pyp-18 dpdt 3pdt pt11 pt11qn ptp-1-3 ? ptp-12 ? 4pdt pt14 pt14qn ptp-1 ptp-10 ? ? relay pc terminal socket relay hold-down clip standard push-to-test rc circuit spdt pt08-0 pyc-p pyc-p2 pyc-1 dpdt 3pdt pt11-0 4pdt pt14-0
general purpose relay ly 3 specifications contact data coil data 1- and 2-pole types ? ac 1- and 2-pole types ? dc note: 1. the rated current and coil resistance are measured at a coil temperature of 23c (73f) with tolerances of +15%, -20% for ac ra ted current, and 15% for dc rated coil resistance. 2. the ac coil resistance and inductance are reference values at 60 hz. 3. the performance characteristics are measured at a coil temperature of 23c (73f). 4. class b coil insulation is available. load single contact bifurcated contact spdt dpdt, 3pdt, 4pdt dpdt resistive load (p.f. = 1) inductive load (p.f. = 0.4) (l/r = 7 ms) resistive load (p.f. = 1) inductive load (p.f. = 0.4) (l/r = 7 ms) resistive load (p.f. = 1) inductive load (p.f. = 0.4) (l/r = 7 ms) rated load 15 a at 110 vac 10 a at 110 vac 10 a at 110 vac 7.5 a at 110 vac 5 a at 110 vac 4 a at 110 vac 15 a at 24 vdc 7 a at 24 vdc 10 a at 24 vdc 5 a at 24 vdc 5 a at 24 vdc 4 a at 24 vdc contact material ag-alloy carry current 15 a10 a7 a max. operating voltage 250 vac 125 vdc max. operating current 15 a10 a7 a max. switching capacity 1,700 va 1,100 va 1,100 va 830 va 550 va 440 va 360 w170 w240 w120 w120 w 100 w min. permissible load 100 ma, 5 vdc 10 ma, 5 vdc rated voltage (v) rated current (ma) coil resistance ( ? ) coil inductance (ref. value) (h) pick-up voltage dropout voltage maximum voltage power consumption (va, w) armature off armature on 50 hz 60 hz (% of rated voltage) 6 214.10 183 12.20 0.04 0.08 80% max. 30% min. 110% approx. 1.00 to 1.20 (60 hz) 12 106.50 91 46 0.17 0.33 24 53.80 46 180 0.69 1.30 50 25.70 22 788 3.22 5.66 100/110 11.70/12.90 10/11 3,750 14.54 24.60 approx. 0.90 to 1.10 (60 hz) 110/120 9.90/10.80 8.40/9.20 4,430 19.20 32.10 200/220 6.20/6.80 5.30/5.80 12,950 54.75 94.07 220/240 4.80/5.30 4.20/4.60 18,790 83.50 136.40 rated voltage (v) rated current (ma) coil resistance ( ? ) coil inductance (ref. value) (h) pick-up voltage dropout voltage maximum voltage power consumption (va, w) armature off armature on (% of rated voltage) 6 150 40 0.16 0.33 80% max. 10% min. 110% approx. 0.90 12 75 160 0.73 1.37 24 36.90 650 3.20 5.72 48 18.50 2,600 10.60 21 100/110 9.10/10 11,000 45.60 86.20
4 general purpose relay ly 3-pole type ? ac 3-pole type ? dc 4-pole type ? ac 4-pole type ? dc note: 1. the rated current and coil resistance are measured at a coil temperature of 23c (73f) with tolerances of +15%, -20% for ac ra ted current, and 15% for dc rated coil resistance. 2. the ac coil resistance and inductance are reference values at 60 hz. 3. the performance characteristics are measured at a coil temperature of 23c (73f). 4. class b coil insulation is available. rated voltage (v) rated current (ma) coil resistance ( ? ) coil inductance (ref. value) (h) pick-up voltage dropout voltage maximum voltage power consumption (va, w) 50 hz 60 hz armature off armature on (% of rated voltage) 6 310 270 6.70 0.03 0.05 80% max. 30% min. 110% approx. 1.60 to 2.00 (60 hz) 12 159 134 24 0.12 0.21 24 80 67 100 0.44 0.79 50 38 33 410 2.24 3.87 100/110 15.90/18.30 13.60/15.60 2,300 10.50 18.50 120 17.30 14.8 2,450 11.50 20.60 200/220 10.50/11.60 9.00/9.90 8,650 34.80 59.50 240 9.40 8 10,400 38.60 74.60 rated voltage (v) rated current (ma) coil resistance ( ? ) coil inductance (ref. value) (h) pick-up voltage dropout voltage maximum voltage power consumption (va, w) armature off armature on (% of rated voltage) 6 234 25.70 0.11 0.21 80% max. 10% min. 110% approx. 1.40 12 112 107 0.45 0.98 24 58.60 410 1.89 3.87 48 28.20 1,700 8.53 13.90 100/110 12.70/13 8,500 29.60 54.30 rated voltage (v) rated current (ma) coil resistance ( ? ) coil inductance (ref. value) (h) pick-up voltage dropout voltage maximum voltage power consumption (va, w) armature off armature on 50 hz 60 hz (% of rated voltage) 6 386 330 5 0.02 0.04 80% max. 30% min. 110% approx. 1.95 to 2.50 (60 hz) 12 199 170 20 0.10 0.17 24 93.60 80 78 0.38 0.67 50 46.80 40 350 1.74 2.88 100/110 22.50/25.50 19/21.80 1,800 10.50 17.30 120 19.00 16.40 2,200 9.30 19 200/220 11.50/13.10 9.80/11.20 6,700 33.10 57.90 240 11.00 9.50 9,000 33.20 63.40 rated voltage (v) rated current (ma) coil resistance ( ? ) coil inductance (ref. value) (h) pick-up voltage dropout voltage maximum voltage power consumption (va, w) armature off armature on (% of rated voltage) 6 240 25 0.09 0.21 80% max. 10% min. 110% approx. 1.50 12 120 100 0.39 0.84 24 69 350 1.41 2.91 48 30 1,600 6.39 13.60 100/110 15/15.90 6,900 32 63.70
general purpose relay ly 5 characteristics note: data shown are of initial value. characteristic data maximum switching capacity electrical service life contact resistance 50 m ? max. operate time 25 ms max. release time 25 ms max. operating frequency mechanically 18,000 operations/hour under rated load 1,800 operations/hour insulation resistance 100 m ? min. (at 500 vdc) dielectric strength 2,000 vac, 50/60 hz for 1 minute 1,000 vac, 50/60 hz for 1 minute between contacts of same polarity vibration mechanical durability 10 to 55 hz, 1.00 mm (0.04 in) double amplitude malfunction durability 10 to 55 hz, 1.00 mm (0.04 in) double amplitude shock mechanical durability 1,000 m/s 2 (approx. 100 g) malfunction durability 200 m/s 2 (approx. 20 g) ambient temperature operating -40 to 70c (-40 to 158f) (over 4a carry currents 55c max.) humidity 35 to 85% rh service life mechanically ac: 50 million operations min. (at operating frequency of 18,000 operations/hour) dc: 100 million operations min. (at operating frequency of 18,000 operations/hour) electrically see ?characteristic data? weight spdt, dpdt: approx. 40 g (1.41 oz), 3pdt: approx. 50 g (1.76 oz) 4pdt: approx. 70 g (2.47 oz) ly 1 ly 2 ly 3 , ly 4 ly 2 z rated operating voltage (v) rated operating current (a) rated operating voltage (v) rated operating current (a) rated operating voltage (v) rated operating current (a) rated operating voltage (v) r a t e d opera ti ng curren t (a) ly 1 ly 2 ly 3 , ly 4 ly 2 z switching current (a) service life (x10 6 operations) switching current (a) service life (x10 6 operations) switching current (a) service life (x10 6 operations) switching current (a) service life (x10 6 operations)
6 general purpose relay ly dimensions unit: mm (inch) relays note: the above drawing shows ly1f. with ly2f, dimension ?*? should read as eight 3.05 mm (0.12 in) dia. holes. ly 1 ly 2 terminal arrangement (bottom view) terminal arrangement (bottom view) ly 3 ly 4 terminal arrangement (bottom view) terminal arrangement (bottom view) ly1-0, ly2-0, ly3-0, ly4-0 mounting holes for ly1-0, ly2-0, ly3-0, ly4-0 (bottom view) note: the above drawing shows ly2-0. with ly1-0, dimension ?*? should read as eight 6.35 (.25). sptd dpdt 3pdt 4pdt ly1f, ly2f ly3f mounting holes mounting holes
general purpose relay ly 7 ly4f mounting holes ly1s, ly2s round hole rectangular hole note: the above drawing shows ly2s-us. with ly1s-us, dimension ?*? should read as eight 2.03 mm (0.08 in) dia. holes. ly3s round hole rectangular hole ly4s round hole rectangular hole
8 general purpose relay ly accessories unit: mm (inch) track mounted sockets (ul file no. e87929) (csa report no. lr31928) track mounting sockets (ul file no. e87929) (csa report no. lr31928) note: 1. ul/csa does not apply to wire wrap (q) type sockets. 2. values in brackets for ly ? cr. 3. ptf08a-e and ptf14a-e = touch safe screws. height = 33 mm max. back connecting socket (ul file no. e87929) (csa report no. lr31928) ptf08a (see note 3) terminal arrangement/ mounting holes (top view) ptf11a terminal arrangement/ mounting holes (top view) ptf14a (see note 3) terminal arrangement/ mounting holes (top view) mounting height of relay with socket (applies to all ptf ? a sockets) pt08 terminal arrangement/ (bottom view) pt11 terminal arrangement/ (bottom view)
general purpose relay ly 9 back connecting socket (ul file no. e87929) (csa report no. lr31928) note: values in brackets for ly ? cr. back connecting socket (ul file no. e87929) (csa report no. lr31928) back connecting socket (ul file no. e87929) (csa report no. lr31928) back connecting socket (ul file no. e87929) (csa report no. lr31928) pt14 terminal arrangement (bottom view) mounting height of relay with socket (applies to all pt sockets) pt pt08qn panel cut-out and terminal arrangement are the same as type pt08. pt11qn panel cut-out and terminal arrangement are the same as type pt11. pt14qn panel cut-out and terminal arrangement are the same as type pt14. pt08-0 terminal arrangement is the same as type pt08. mounting holes (bottom view) pt11a terminal arrangement is the same as type pt11. mounting holes (bottom view) pt14-0 terminal arrangement is the same as type pt14. mounting holes (bottom view)
10 general purpose relay ly unit: mm (inch) relay hold-down clips relay hold-down clips mounting track/end plate/spacer pyc-a1 for ptf ? a socket pyc-s for relay mounting plates (applicable to type pyp-1 and pyp-18 socket mounting plates only.) pyc-p for pt ? socket pyc-p2 for push-to-test button type with pt ? socket y92h-3 for rc circuit type pyc-1 for rc circuit type pfp-100n/pfp-50n mounting track pfp-m end plate
general purpose relay ly 11 *this dimension is 14.99 mm (0.59 in) on both ends in the case of pfp-100n, but on one end in the case of pfp-50n. **l = length pfp-50n l = 497.84 mm (19.60 in) pfp-100n l = 990.60 mm (39.00 in) pfp-100n2 l = 990.60 mm (39.00 in) ***a total of twelve 24.89 x 4.57 mm (0.98 x 0.18 in) elliptic holes are provided, with six holes cut from each end of the trac k at a pitch of 9.91 (0.39) between holes. pfp-100n2 mounting track pfp-s spacer socket mounting plates [t=1.52 (.06)] number of socket specs. socket needed 1 10 12 18 pt08, pt08qn pyp-1 ? ? pyp-18 pt11, pt11qn ptp-1-3 ? ptp-1-2 _ pt14, pt14qn ptp-1 ptp-10 ? ? ptp-10 ptp-12 pyp-1 ptp-1-3 ptp-1 pyp-18 ptp-10 ptp-12
12 general purpose relay ly relay options led indicator specifications and dimensions same as the standard type with the following exception. with the led indicator type, the rated cu rrent is approxi- mately 0 to 5.0 ma higher than the standard type. terminal arrangement/internal connections (bottom view) ly2n note: 1. the coil terminals 10 and 11 of type ly3n become (-) and (+) and terminals 13 and 14 of type ly4n become (-) and (+), respectiv ely. 2. pay special attention to the polarities when using the dc type. diode surge suppression specifications and dimensions same as the standard type with the following exception. ambient operating temperature: -25 to 40 c (-13 to 104f) terminal arrangement/internal connections (bottom view) ly2(n)-d(2) note: 1. pay special attention to the polarities when using the dc type. 2. the release time is somewhat longer, but satisfies the standard specifications of 25 ms. 3. the reverse-breakdown voltage of the diode is 1,000 vdc. 4. available on dc versions only. 1 3 5 7 2 4 6 8 dc coil rating type ac coil rating type 1 3 5 7 2 4 6 8 without diode with diode ly 2 - d 6, 12, 24, 48 100/110 vdc ly2 n -d 2 6, 12, 24, 48 vdc ly 2 n - d 2 100/110 vdc
general purpose relay ly 13 relay options rc circuit specifications and dimensions same as the standard type with the following exceptions. characteristic data note: 1. the above drawing shows ly2(z)-cr. with ly1-cr, ?*? should read eight 2.03 mm (0.08 in) dia. holes. 2. available on ac versions only. push-to-test button specifications and dimensions same as the standard type with the following exceptions. note: type ly112 has the same dimensions and appearances as type ly212 shown except that dimensions ?*? is 2.03 mm (0.08 in) dia. hol es. without rc circuit with rc circuit ly1-cr, ly2(z)-cr terminal arrangement/internal connections (bottom view) ly 1 - c r ly 2 ( z ) - c r ly ? 12 ly112, ly212 ly312 ly412
14 general purpose relay ly approvals ul recognized type (file no. e41643) csa certified type (file no. lr31928) vde approved type (file no. 9903 [spdt, dpdt & 3pdt], file no. 9947 [4pdt]) lr (lloyd's register) approved type (file no. 562kob-204523) sev listed type (file no. d7 91/82 [2- & 4-pole], d 91/204a [1- & 3-pole]) note: 1. the rated values approved by each of the safety standards (e.g., ul, csa, vde, and sev) may be different from the performance c har- acteristics individually defined in this catalog. 2. in the interest of product improvement, specifications are subject to change. type contact form coil ratings contact ratings ly ? spdt 6 to 240 vac 15 a, 240 vac (inductive) 6 to 120 vdc 15 a, 28 vdc (resistive) tv-5 (actv) 1/2 hp, 120 vac (motor) ly ? dpdt 13 a, 120 vac (resistive) 12 a, 240 vac (inductive) 10 a, 28 vdc (resistive) tv-3 (actv) 1/2 hp, 120 vac (motor) ly ? 3pdt 10 a, 240 vac (inductive) 4pdt 10 a, 28 vdc (resistive) 1/2 hp, 240 vac (motor) type contact form coil ratings contact ratings ly ? spdt 6 to 240 vac 15 a, 120 vac (inductive) 6 to 120 vdc 10 a, 240 vac (inductive) 15 a, 28 vdc (resistive) tv-5 (actv) ly ? dpdt 13 a, 28 vdc (resistive) 12 a, 120 vac (inductive) 10 a, 240 vac (inductive) 1/3 hp, 120 vac (motor) tv-3 (actv) ly ? 3pdt 10 a, 240 vac (inductive) 4pdt 10 a, 28 vdc (resistive) type contact form coil ratings contact ratings ly ? -vd spdt 6, 12, 24, 50, 10 a, 220 vac (resistive) 110, 220 vac 10 a, 28 vdc (resistive) and 6, 12, 24, 7 a, 220 vac (inductive) 48, 110 vdc 7 a, 28 vdc (inductive) ly ? -vd dpdt 7 a, 220 vac (resistive) 3pdt 7 a, 28 vdc (resistive) 4pdt 4 a, 220 vac (inductive) 4 a, 28 vdc (inductive) type contact form coil ratings contact ratings ly ? dpdt 6 to 240 vac 7.5 a, 230 vac (inductive) 4pdt 6 to 110 vdc 5 a, 24 vdc (inductive) type contact form coil ratings contact ratings ly ? -sv spdt 6 to 240 vac 15 a, 220 vac (resistive) 6 to 110 vdc 15 a, 24 vdc (resistive) ly ? -sv dpdt 10 a, 220 vac (resistive) 3pdt 10 a, 24 vdc (resistive) 4pdt
general purpose relay ly 15 omron electronic components, llc terms and conditions of sales 1. definitions : the words used herein are defined as follows. (a) terms: these terms and conditions (b) seller: omron electronic components llc and its subsidiaries (c) buyer: the buyer of products, including any end user in section iii through vi (d) products: products and/or services of seller (e) including: including without limitation 2. offer; acceptance: these terms are deemed part of all quotations, acknowledgments, invoices, purchase orders and other documents, whether electronic or in writing, relating to the sale of products by seller. seller hereby objects to any terms proposed in buyer's purchase order or other documents which are inconsistent with, or in addition to, these te r ms . 3. distributor : any distributor shall inform its customer of the contents after and including section iii of these terms. 1. prices; payment : all prices stated are current, subject to change without notice by seller. buyer agrees to pay the price in effect at time of shipment. payments for products received are due net 30 days unless otherwise stated in the invoice. buyer shall have no right to set off any amounts against the amount owing in respect of this invoice. 2. discounts : cash discounts, if any, will apply only on the net amount of invoices sent to buyer after deducting transportation charges, taxes and duties, and will be allowed only if (a) the invoice is paid according to seller's payment terms and (b) buyer has no past due amounts owing to seller. 3. interest : seller, at its option, may charge buyer 1.5% interest per month or the maximum legal rate, whichever is less, on any balance not paid within the stated terms. 4. orders : seller will accept no order less than 200 u.s. dollars net billing. 5. currencies : if the prices quoted herein are in a currency other than u.s. dollars, buyer shall make remittance to seller at the then current exchange rate most favorable to seller; provided that if remittance is not made when due, buyer will convert the amount to u.s. dollars at the then current exchange rate most favorable to seller available during the period between the due date and the date remittance is actually made. 6. governmental approvals : buyer shall be responsible for all costs involved in obtaining any government approvals regarding the importation or sale of the products. 7. taxes : all taxes, duties and other governmental charges (other than general real property and income taxes) , including any interest or penalties thereon, imposed directly or indirectly on seller or required to be collected directly or indirectly by seller for the manufacture, production, sale, delivery, importation, consumption or use of the products sold hereunder (including customs duties and sales, excise, use, turnover and license taxes) shall be charged to and remitted by buyer to seller. 8. financial : if the financial position of buyer at any time becomes unsatisfactory to seller, seller reserves the right to stop shipments or require satisfactory security or payment in advance. if buyer fails to make payment or otherwise comply with these terms or any related agreement, seller may (without liability and in addition to other remedies) cancel any unshipped portion of products sold hereunder and stop any products in transit until buyer pays all amounts, including amounts payable hereunder, whether or not then due, which are owing to it by buyer. buyer shall in any event remain liable for all unpaid accounts. 9. cancellation; etc: orders are not subject to rescheduling or cancellation unless buyer indemnifies seller fully against all costs or expenses arising in connection therewith. 10. force majeure : seller shall not be liable for any delay or failure in delivery resulting from causes beyond its control, including earthquakes, fires, floods, strikes or other labor disputes, shortage of labor or materials, accidents to machinery, acts of sabotage, riots, delay in or lack of transportation or the requirements of any government authority. 11. shipping; delivery: unless otherwise expressly agreed in writing by seller: (a) all sales and shipments of products shall be fob shipping point (unless otherwise stated in writing by seller) , at which point title to and all risk of loss of the products shall pass from seller to buyer, provided that seller shall retain a security interest in the products until the full purchase price is paid by buyer; (b) delivery and shipping dates are estimates only; and (c) seller will package products as it deems proper for protection against normal handling and extra charges apply to special conditions. 12. claims: any claim by buyer against seller for shortage or damage to the products occurring before delivery to the carrier must be presented in detail in writing to seller within 30 days of receipt of shipment. 1. suitability: it is the buyer?s sole respoinsibility to ensure that any omron product is fit and sufficient for use in a motorized vehicle application. buyer shall be solely responsible for determining appropriateness of the particular product with respect to the buyer?s application including (a) electrical or electronic components, (b) circuits, (c) system assemblies, (d) end product, (e) system, (f) materials or substances or (g) operating environment. buyer acknowledges that it alone has determined that the products will meet their requirements of the intended use in all cases. buyer must know and observe all prohibitions of use applicable to the product/s. 2. use with attention: the followings are some examples of applications for which particular attention must be given. this is not intended to be an exhaustive list of all possible use of any product, nor to imply that any use listed may be suitable for any product: (a) outdoor use, use involving potential chemical contamination or electrical interference. (b) use in consumer products or any use in significant quantities. (c) energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. (d) systems, machines, and equipment that could present a risk to life or property. 3. prohibited use: never use the product for an application involving serious risk to life or property without ensuring that the system as a whole has been designed to address the risks, and that the product is properly rated and installed for the intended use within the overall equipment or system. 4. motorized vehicle application: use of any product/s for a motorized vehicle application must be expressly stated in the specification by seller. 5. programmable products: seller shall not be responsible for the buyer's programming of a programmable product. 1. warranty : seller's exclusive warranty is that the products will be free from defects in materials and workmanship for a period of twelve months from the date of sale by seller (or such other period expressed in writing by seller). seller makes no warranty or representation, express or implied, about all other warranties, non-infringement, merchantability or fitness for a particular purpose of the products. 2. buyer remedy : seller's sole obligation hereunder shall be to replace (in the form originally shipped with buyer responsible for labor charges for removal or replacement thereof) the non-complying product or, at seller's election, to repay or credit buyer an amount equal to the purchase price of the product; provided that there shall be no liability for seller or its affiliates unless seller's analysis confirms that the products were handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate modification. return of any products by buyer must be approved in writing by seller before shipment. 3. limitation on liability : seller and its affiliates shall not be liable for special, indirect, incidental or consequential damages, loss of profits or production or commercial loss in any way connected with the products, whether such claim is based in contract, warranty, negligence or strict liability. further, in no event shall liability of seller or its affilitates exceed the individual price of the product on which liability is asserted. 4. indemnities : buyer shall indemnify and hold harmless seller, its affiliates and its employees from and against all liabilities, losses, claims, costs and expenses ( including attorney's fees and expenses ) related to any claim, investigation, litigation or proceeding ( whether or not seller is a party ) which arises or is alleged to arise from buyer's acts or omissions under these terms or in any way with respect to the products. 1. intellectual property : the intellectual property embodied in the products is the exclusive property of seller and its affiliates and buyer shall not attempt to duplicate it in any way without the written permission of seller. buyer (at its own expense) shall indemnify and hold harmless seller and defend or settle any action brought against seller to the extent that it is based on a claim that any product made to buyer specifications infringed intellectual property rights of another party. 2. property; confidentiality : notwithstanding any charges to buyer for engineering or tooling, all engineering and tooling shall remain the exclusive property of seller. all information and materials supplied by seller to buyer relating to the products are confidential and proprietary, and buyer shall limit distribution thereof to its trusted employees and strictly prevent disclosure to any third party. 3. performance data : performance data is provided as a guide in determining suitability and does not constitute a warranty. it may represent the result of seller's test conditions, and the users must correlate it to actual application requirements. 4. change in specifications : product specifications and description may be changed at any time based on improvements or other reasons. it is seller?s practice to change part numbers when published ratings or features are changed, or when significant engineering changes are made. however, some specifications of the product may be changed without any notice. 5. errors and omissions : the information on seller?s website or in other documentation has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical or proofreading errors or omissions. 6. export controls : buyer shall comply with all applicable laws, regulations and licenses regarding (a) export of the products or information provided by seller; (b) sale of products to forbidden or other proscribed persons or organizations; (c)disclosure to non-citizens of regulated technology or information. 1. waiver : no failure or delay by seller in exercising any right and no course of dealing between buyer and seller shall operate as a waiver of rights by seller. 2. assignment : buyer may not assign its rights hereunder without seller's written consent. 3. law : these terms are governed by illinois law (without regard to conflict of laws) . federal and state courts in illinois have exclusive jurisdiction for any dispute hereunder. 4. amendment : these terms constitute the entire agreement between buyer and seller relating to the products, and no provision may be changed or waived unless in writing signed by the parties. 5. severability : if any provision hereof is rendered ineffective or invalid, such provision shall not invalidate any other provision. i. general ii. sales iii. pre cautions iv. warranty and limitation v. information; etc. vi. miscellaneous
16 general purpose relay ly certain precautions on specifications and use 1. suitability for use . seller shall not be responsible for conformity with any stan- dards, codes or regulations which apply to the combination of the product in buyer's application or use of the product. at buyer's request, seller will pro- vide applicable third party certification documents identifying ratings and limi- tations of use which apply to the product. this information by itself is not sufficient for a complete determination of the suitability of the product in com- bination with the end product, machine, system, or other application or use. buyer shall be solely responsible for determining appropriateness of the par- ticular product with respect to buyer's application, product or system. buyer shall take application responsibility in all cases but the following is a non- exhaustive list of applications for which particular attention must be given: (i) outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this document. (ii) energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. (iii) use in consumer products or any use in significant quantities. (iv) systems, machines and equipment that could present a risk to life or property. please know and observe all prohibitions of use applicable to this product. never use the product for an application involving serious risk to life or property without ensuring that the system as a whole has been designed to a ddress the risks, and that the omron product is properly rated and installed for the intended use within the overall equipment or system. 2. programmable products . seller shall not be responsible for the user's programming of a programmable product, or any consequence thereof. 3. performance data . performance data given in this publication is provided as a guide for the user in determining suitability and does not constitute a war- ranty. it may represent the result of seller's test conditions, and the users must correlate it to actual application requirements. actual performance is subject to seller's warranty and limitations of liability. 4. change in specifications . product specifications and accessories may be changed at any time based on improvements and other reasons. it is our prac- tice to change part numbers when published ratings or features are changed, or when significant construction changes are made. however, some specifica- tions of the product may be changed without any notice. when in doubt, spe- cial part numbers may be assigned to fix or establish key specifications for your application. please consult with your seller representative at any time to confirm actual specifications of purchased product. 5. errors and omissions . the information in this publication has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical or proofreading errors, or omissions. 6. rohs compliance . where indicated, our products currently comply, to the best of our knowledge as of the date of this publication, with the requirements of the european union's directive on the restriction of certain hazardous substances ("rohs"), although the requirements of rohs do not take effect until july 2006. these requirements may be subject to change. please consult our website for current information. omron on-line global - http://www.omron.com usa - http://www.components.omron.com cat. no. j01c-e-01 printed in usa omron electronic components llc 55 e. commerce drive, suite b schaumburg, il 60173 847-882-2288 01/07 specifications subject to change without notice complete ?terms and conditions of sale? for product purchase and use are on omron?s website at http://www.components.omron.com ? under the ?about us? tab, in the legal matters section. all dimensions shown are in millimeters. to convert millimeters into inches, multiply by 0.03937. to convert grams into ounces, multiply by 0.03527.


▲Up To Search▲   

 
Price & Availability of LY2ZN-D2-AC110

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X